IBM MODES
Horizontal Vertical
Mode Resolution
Total
Nominal
Frequency
+/- .5kHz
Sync
Polarity
Nominal
Freq.
+/- 1 Hz
Sync
Polarity
Nominal
Pixel
Clock (MHz)
DOS 720x400@70Hz 900 x 449 31.469 N 70.087 P 28.322
DOS 640x350@70Hz 800 x 449 31.469 N 70.087 P 25.175
MAC MODES
VGA 640x480@67Hz 864x525 35.000 N 66.667 N 30.240
SVGA 832x624@75Hz 1152x667 49.725 N 74.551 N 57.2832
Note: All modes will automatically optimize the screen size with “ AUTO-config “ function, except 3
Dos- Modes: 720 x 400@70hz, 640x350@70hz, 640x400@70hz
4.3 POWER SUPPLY REQUIREMENT
4.3.1 INPUT REQUIREMENT
PARAMETER RANGE CONDITION
Input Voltage 100 to 240VAC RMS Universal input full range
Input Frequency
60Hz @ 100VAC to 50Hz
@ 240VAC
Input Current Less than 2.0 Amps RMS
Input voltage 100 VAC RMS; 60 Hertz.
Parameter must be reached within 3 seconds
of turn-on.
Less than 1.0 Amps RMS
Input voltage 220 VAC RMS ; 50 Hertz.
Parameter must be reached within 3 seconds
of turn-on.
Input Power Less than 40 Watts
Power factor > 0.5
Input voltage 120 VAC RMS ; 60
Hertz
Inrush Current Less than 30 A peak
Input voltage 100 VAC RMS; 60 Hertz at all
Phase (0, 90, 180, 270 degree)
Less than 50 A peak
Input voltage 240 VAC RMS; 50 Hertz at all
Phase (0, 90, 180, 270 degree)
Input Fusing
Fuse should be located internal to
the adapter, easily accessible
when the cover is removed
Fuse must be UL/CSA approved. Fuse value
must no have to change for 115 VAC or 230
VAC operation
Leakage Current
Less than 3.5 mA Input voltage 240 Volts RMS; 50 Hertz
Hi-Pot
Primary to secondary 1.5KVAC for 1 Minute (leakage current
10mA)
1.8KVAC for 1 Minute (leakage current
10mA)
3.0KVAC for 1 Minute (leakage current
10mA)
without Y-cap & Coupling cap.